Detailed Energy Audit
Detailed Energy Audit
Detailed Energy Audit (ASHRAE Level 2/BEE Level 2) provides comprehensive energy use analysis with quantitative savings potential through detailed measurements and end-use segregation.
Scope of Work
Phase 1: Pre-Audit
- 12-24 months utility bill analysis and benchmarking
- Facility walkthrough identifying major energy consumers
- Data collection: equipment lists, operating schedules, production data
Phase 2: Detailed Measurements
System | Measurements |
Electrical | 7-day power quality monitoring (PF, THD, load profile) |
Motors (>10HP) | No-load/part-load efficiency testing |
Compressed Air | Leak detection, pressure cascade survey |
Pumps/Fans | Flow/pressure verification, impeller sizing |
Lighting | Lux levels, operating hours, ballast efficiency |
HVAC | Chiller COP, AHU static pressure, cooling tower approach |
Phase 3: Analysis & Reporting
- Energy balance diagram (input vs. end-use)
- ECM list with quantified savings (kWh, ₹ savings)
- Simple payback analysis (<3 years prioritized)
- Implementation roadmap with responsibilities
Deliverables:
- Detailed report (40-60 pages) with thermographic scans
- Executive summary for management
- Prioritized action plan with cost estimates.